Timberwolf

Technical Specifications

Classic Series

arcticspas hot tub classic series timberwolf signature

Details

Outside Dimensions:

85’’ x 69’’ | 217 x 174 cm | 7′ x 6′

Height:

39’’ | 98 cm | 3′

Dry Weight:

611 Lbs | 277 Kg

Wet Weight:

2560 Lbs | 1161 Kg

Ground Pressure – FULL (lbs/ft2):

69.7

Water Capacity:

234 Gallons | 884 Liters

Heater(Watts):

NA / Euro 4000 W

Electrical Requirements North America
(A = actual / B = breaker)
:

240 Volts / 6 Gauge Wire
1 Pump / A32amp / B40amp
2 Pumps / A40amp / B50amp
Upgraded Classic
240 Volts / 6 Gauge Wire
1 Pump / A40amp / B50amp
2 Pumps / A40amp / B50amp
115 Volts / 14 Gauge Wire
1 Pump / A12amp / B15amp

Equipment Location

EcoPak

arcticspas Equipment Location Timberwolf EcoPack
INYE Spa Pack
arcticspas Equipment Location Timberwolf INYE Spa Pack

Dimensioned Drawings

Dimensioned Drawings TIMBERWOLF
Dimensioned Drawings TIMBERWOLF

Recommended Site Access and Preparation

CLASSIC SERIES WITH FOREVER FLOOR®

Most Spas Require 44” Clearance to get through gates, between houses and side fences and around corners. 9’-10’ of overhead clearance in order to move the spa into place.

To select a location for your new Arctic Spa with Forever Floor® will require a flat compact surface.

If you are using 4X4 railroad ties, they should be a maximum of 12-inch centers to properly support the entire underside of your spa.
Balconies and decks should be constructed to meet all builder codes and should be able to support up to exceed 100lbs/square foot. Remember that a gallon of water weighs roughly about 10 lbs

Your Spa can weigh as much a 1000lbs (454kg)